While ANSI standards mandate that emergency showers and eyewashes should be activated weekly and completely inspected once annually, the actual testing results are rarely recorded in a central database. (Haws photo)

The Value of Wireless Alarms and Monitoring Systems on Emergency Equipment

Not only will these systems help to ensure employee safety, they can make it easier for facilities to stay in compliance with OSHA and ANSI standards.

Federal safety regulations set forth by the Occupational Safety and Health Administration (OSHA) and the American National Standards Institute (ANSI) make the importance of safety equipment in potentially dangerous working environments clear. The stringent guidelines for emergency showers and eyewashes, however, don’t extend to the inclusion of mandatory alarm and electronic monitoring systems on this equipment. This oversight can create unsafe working conditions in even the most well equipped facilities. Not only is this dangerous, it's also a potential liability.

Meeting the Standard—But Just Barely
From university laboratories to industrial facilities, safety shower and eyewash stations are ready to perform in the event of an emergency. But while the standards are explicit when it comes to the design, certification, installation, testing, and maintenance of emergency equipment, the importance of accompanying alarm and monitoring systems is overlooked.

In fact, it’s possible for a facility to technically meet OSHA and ANSI standards without either—and that's a problem.

Implementing best practices with the addition of both alarm and wireless monitoring systems is the best way for workplaces to exceed normal expectations by creating superior emergency response procedures. Not only will this help to ensure employee safety, it can make it easier for facilities to stay in compliance with OSHA and ANSI standards.

Function First
Alarm and wireless monitoring systems are exactly what you'd imagine. An alarm system is intended to notify the management and personnel of a facility about when and where safety equipment is being used. Electronic monitoring systems are specifically designed to automate inspections, log data, document test results, record when and where and for how long specific equipment is used, and then store this information in a database or on a remote server for instant access.

While it would seem that both alarm and monitoring systems offer convenience and further enhance the safety and reliability of emergency equipment, they are few and far between. But why?

Making Necessary Systems Optional
Unfortunately, the supplementation of existing emergency equipment with alarm and monitoring systems isn’t explicitly mandated. While OSHA strongly recommends that both safety showers and eyewashes should be equipped with alarm systems, it isn't a requirement. And that means nine out of 10 stations in most facilities don't have one.

The language in federal mandates is equally vague when it comes to the importance of electronically monitoring emergency equipment. Many equipment manufacturers don't offer monitoring. This means that facility operators have no details as to when, where, and even if any of their safety systems has been in use, making it nearly impossible to determine whether equipment is operating and being used appropriately. And while ANSI standards mandate that emergency showers and eyewashes should be activated weekly and completely inspected once annually, the actual testing results are rarely recorded in a central database. This can result in failure to meet minimum compliance standards, opening facilities to potential legal liability.

Equally dangerous is the lack of an accompanying alarm system on emergency equipment. A typical alarm system on an emergency shower or eyewash has flashing lights and an audible alarm, both of which are designed to alert management immediately that specific safety equipment is in use. When an emergency strikes, an alarm system is the fastest, most effective way of ensuring a quick response to the injured employee, which is often necessary to minimize injuries. Without alarms, injured workers may be on their own—a scenario that can quickly make a bad situation far worse.

A Wireless Solution
In many cases, the lack of alarm and electrical monitoring systems boils down to old facilities with dated equipment that would be too difficult and expensive to retrofit with hard-wired systems. Wireless switches are a cost-effective solution to these problems. These wireless systems easily install and are easy to maintain on a variety of safety equipment, including safety shower and eyewash stations. It can help facilities reduce maintenance costs and help them stay in compliance with federal safety regulations while preventing or reducing workplace injuries.

Unlike hard-wired systems, which are typically difficult and costly to install, wireless switches require no wiring or electrical connectors. A pair of over-the-counter batteries is sufficient to power the system’s switches over an entire year. The entire wireless system runs on a 2.4 GHz ISM band that consumes minimal power for better batter life. And this band has a low susceptibility to rain, sleet, snow, moisture, and dust—an important consideration in many facilities.

Wireless systems will maintain a strong RF signal as long as the wireless switch is within 1,000 feet of the wireless receiver module with an unobstructed line of sight between them. Signal strength also can be improved with higher-gain antennas.

Another advantage is in their installation. In most wired systems, the water valves in the safety stations are electronically connected to some kind of alarm or buzzer in central dispatch areas. This alerts appropriate personnel when a specific piece of emergency equipment is activated. But because the alarm is activated when water flows through a pipe, the alarm can be disabled if the water source is cut off, which could happen if pipes freeze.

Wireless switches are installed on the mechanical linkage of shower pull-chains. Regardless of what happens with water in the pipes, the wireless system will still raise the alarm to indicate the specific safety station that has been activated.

Depending on existing features, either a hard-wired digital signal or an Ethernet IP signal can be used to activate the alarm. A 16-bit PAN ID, 16-bit address, and 128-bit AES security key virtually eliminate any risk of cross-talk or hacking.

An Easy Improvement to Existing Emergency Equipment
A wireless alarm and monitoring system is a fast, simple way to improve existing safety equipment. From initiating an emergency response as soon as safety equipment is engaged to maintaining detailed records of when stations are used, tested, and maintained, these wireless systems can create safer, more responsive working environments.

This article originally appeared in the July 2016 issue of Occupational Health & Safety.

Product Showcase

  • Kestrel 5400 Heat Stress Tracker WBGT Monitoring for Workplace Safety

    Ensure safety with the Kestrel® 5400 Heat Stress Tracker, the go-to choice for safety professionals and endorsed by the Heat Safety & Performance Coalition. This robust, waterless WBGT meter is ideal for both indoor and outdoor environments, offering advanced monitoring and data logging essential for OSHA compliance. It features pre-programmed ACGIH guidelines and alert settings to quickly signal critical conditions. Integrated with the cloud-based Ambient Weather Network, the 5400 allows managers to view, track, and log job site conditions remotely, ensuring constant awareness of potential hazards. Its capability for real-time mobile alerts and remote data access promotes proactive safety management and workplace protection, solidifying its role as a crucial tool in industrial hygiene. 3

  • Magid® D-ROC® GPD412 21G Ultra-Thin Polyurethane Palm Coated Work Gloves

    Magid’s 21G line is more than just a 21-gauge glove, it’s a revolutionary knitting technology paired with an advanced selection of innovative fibers to create the ultimate in lightweight cut protection. The latest offering in our 21G line provides ANSI A4 cut resistance with unparalleled dexterity and extreme comfort that no other 21-gauge glove on the market can offer! 3

  • AirChek Connect Sampling Pump

    Stay connected to your sampling with the SKC AirChek® Connect Sampling Pump! With its Bluetooth connection to PC and mobile devices, you can monitor AirChek Connect pump operation without disrupting workflow. SKC designed AirChek Connect specifically for all OEHS professionals to ensure accurate, reliable flows from 5 to 5000 ml/min and extreme ease of use. AirChek Connect offers easy touch screen operation and flexibility. It is quality built to serve you and the workers you protect. Ask about special pricing and a demo at AIHA Connect Booth 1003. 3